Etude Par Fragmentographie de Masse de la Cinetique Sanguine D'un Anti-Inflammatoire DU F-1594

A. Hanafiah W.S., Badruzzaman S.

Abstract


Sari. Telah dilakukan penetapan kadar plasmatik dari senyawa p bifenil-4, okso-4, metil-2-butirat (F-1594) sebagai salah satu obat anti inflamasi dengan teknik kombinasi kromatografi gas-spektrometri massa. F-1594 dengan ‘internal standar’ p-bifenil 4-chloro 2’ asetat diekstraksi dari plasma, dipisahkan melalui kromatografi gas yang dilengkapi dengan kolom kapiler kemudian dianalisa secara fragmentografi massa. Dengan menggunakan sedikit cuplikan, cara ini mampu mendeteksi suatu sediaan dengan konsentrasi yang sangat kecil.

 

Abstract. The determination of p-biphenyl-4, oxo-4, methyl-2-butyric acid (F-1594) as an antiinflammatory agent in the human plasma by using gas chromatography-mass spectrometry is described. Quantitation was achieved after extraction from the plasma, F 1594 and p-biphenyl 4-chloro 2’-acetic acid as an internal standard, separated by gas chromatography with the capillary column and analysed by mass fragmentography. This process requires only a very little sample and it enables the detection of very low concentration.


Full Text:

PDF

References


BEYNON, Mass Spectrometry and its Application to Organic Chemistry, Elsevier publishing et Cie, Amsterdam London New York, Prenceton, 1960.

BRET M.C., These de Doctorate s Science Pharmaceutiques de Montpellier, France, 1980.

CAMISH Me., European Journal of Mass Spectrometry in Biochemistry medicine and environmental research, 1980, vol 1. No.4, 7, 31.

WANSAATMADJA H., These de Docotrat de 3 eme cycle, Fac. de Pharmacie de Montpellier, France, 1981.