ANALISIS SIKLUS KOMBINASI GAS DAN UAP

Authors

  • Pawito M Sontowiro

Abstract

In general, the gas exits from gas turbine still has a high temperature. To recover its energy, a Rankine cycle is installed to receive thermal input energy from the gas. For each value of pressure ratio of the Brayton cycle, the optimum total efficiency is largely controlled by the pressure and temperature of steam entering turbine and the steam"?air mass ow rate ratio of the system. With the environment, the uid entering temperature to the turbines, the minimum uids temperatures difference in heat exchangers, and the quality of steam at the exit of steam turbine as constraints, optimum total efficiency of the system is investigated on this report.

References

M.M. El Wakil, "Power Plant Technology" , Mc-Graw Hill Book Company, New York, 1985.

J.B. Stout et al, "A Large Combined Gas Turbine - Steam Turbine Generating Unit" , Proceeding of the American Power Conference, Chicago, Illinois Institute of Technology, 1962.

A Hansson, "The 300MW Combined Cycle and 20MW1GSC Project in Barsebeck" , 3rd International Symposium on Turbo Machinery, Combined Cycle Technologies and Cogeneration, 1989.