Performance Testing of Indonesian Hydrocarbon Refrigerants
Abstract
In conjunction with the CFC phase out, IURC-ES ITB has been concentrating its research of HC refrigerant on 'propane natural butane' (PNB) refrigerant. The test results obtained in IURC-ES ITB during the development of the PNB refrigerant showed that PNB has better performance than PIB and CFC-12. The field tests of PNB also showed the similar results. Recently, to reconfirm the previous test results, the performance of PNB, PIB and CFC-I2 were compared in a series of performance tests in the LTMP Serpong. The tests also show that PNB consistently has better performance compared to PIB and CFC-12. This paper also reports the current development of PNB refrigerant in IURC-ES ITB.
References
A. Suwono, N.P. Tandian, A.D. Pasek, T. Hardianto. T.A.F. Soelaiman, N. Damitri, P. Atmadi, and C. Soekardi, "Retrofit and Conversion of a R-22 Chiller to R-290 and Its Performance Comparison" , Preprints of Seminar on ODS Phase-Out: Solutions for the Refrigeration Sector, pp. (223-1) " (223-6), 1999.
A. Suwono and W. Ardiansyah, "Study on Thermodynamic Properties of Propane/normal butane and its possibility to be used as refrigerant Substitute of R-12" , J. of Mechanical Engineering, 10. 2. 1994 (in Indonesian)
A. Suwono, A.D. Pasek, and N.P. Tandian, "Development of the Application of Propane/n-Butane Mixture as Substitute of CFC Refrigerant", Seminar on Alternative Refrigerants, Bandung, 1996 (in Indonesian)
N. Tandian, Sularso, and A.D. Pasek, Application of Propane-Butane as a Substitute of Refrigerants Containing CFC, Graduate Team Research Grant - URGE Project Progress Report, Bandung, 1996
N.P. Tandian, A. Suwono, C.A. Sylva, and A.D. Pasek, "Application of Propane-Butane Mixtures as Refrigerant in a Milk Cooling Unit" , Proceedings of International Conference on Fluid and Thermal Energy-Conversion '97, Yogyakarta, 1997
N. Tandian, Sularso, and A.D. Pasek, Application of Propane-Butane as a Substitute of Refrigerants Containing CFC, Graduate Team Research Grant - URGE Project Progress Report, Bandung, 1997
A. Suwono, N.P. Tandian, ADA Pasek, T. Hardianto, and T.A.F. Soelaiman, "Indonesian Experiences on Hydrocarbon Application as Refrigerant Substituting the Phased-Out CFC", Proceedings of IIR Conference on Natural Working Fluids, Oslo, 1998
N. Tandian, Sularso, and A.D. Pasek, Application of Propane-Butane as a Substitute of Refrigerants Containing CFC, Graduate Team Research Grant - URGE Project Progress Repon, Bandung, 1998
N.P. Tandian, A. Suwono, and A.D. Pasek, "Application HC-CFC Mixture as Refrigerant to Anticipate the Phasing-Out of CFC and Extending the Use of Recovered CFC", Proceedings of ISASTI '98. Jakarta, 1998
N, Tandian, Sularso, and A.D. Pasek, Application of Propane-Butane as a Substitute of Refrigerants Containing CFC, Graduate Team Research Grant - URGE Project Final Report, Bandung, 1999
N. Damitri, C. Soekardi, B.T. Prasetyo. Sarwono. Kafi'uddin, A. Suwono, A.D. Pasek, and N.P. Tandian, "Performance Comparison of CFC12, HCRIZ and HCR12+LFS as Alternative Refrigerants" Preprints of Seminar on ODS Phase-Out: Solutions" for the Refrigeration Sector, 1999.