Abstract

The type of offshore platform for oil and natural gas exploration that is widely used in Indonesia is steel jacket platform. Jacket type platforms are generally made of tubular steel. During the service life, jacket type platforms often suffer damage to the joints. One preferred repair method for platform structure elements is by grouting. In the API RP 2A WSD NORSOK N-004 regulations, the formulations of tubular joint capacity reinforced by grouting are specified. The formulations in the regulations are empirical equations that need to be examined experimentally in the lab or tested by finite element analysis method. In this study, testing using the finite element method is conducted. The discussion is limited to the type of tubular joint with double skin chord. By finite element analysis, the influence of grout thickness, grout strength, inner chord thickness, and outer chord thickness to capacity of tubular joints reinforced with grout is investigated. From the analysis, it was found that the thickness and strength of the grout do not have a significant effect on increasing tubular joint capacity. While the thickness of both the inner and outer chords have a significant effect on increasing the tubular joint capacity. By comparison, the results of finite element method analysis are quite close to the results based on API regulation and in general the API results are more conservative except for cases with out-of-plane bending load.

Abstrak

Tipe anjungan lepas pantai untuk eksplorasi minyak dan gas alam yang banyak dipakai di lepas pantai Indonesia adalah tipe jaket baja. Anjungan tipe jaket umumnya dibuat dari baja tubular. Dalam masa layannya, anjungan tipe jaket sering mengalami kerusakan pada sambungan (joint). Salah satu metode perbaikan yang disukai untuk elemen struktur anjungan adalah dengan di-grout. Dalam peraturan API RP 2A WSD dan NORSOK N-004 telah diberikan formulasi perhitungan kapasitas sambungan tubular yang diperkuat grout. Formulasi pada peraturan-peraturan ini merupakan persamaan-persamaan empiris yang perlu diperiksa dengan eksperimental di lab atau diuji dengan analisis metode elemen hingga. Pada penelitian ini dilakukan pengujian dengan metode elemen hingga. Pembahasan dibatasi pada tipe sambungan tubular dengan batang utama (chord) ganda. Dengan analisis elemen hingga akan dilihat pengaruh tebal grout, kuat grout, tebal chord dalam, dan tebal chord luar terhadap kapasitas sambungan tubular yang diperkuat di-grout. Dari hasil analisis diperoleh bahwa tebal dan kuat grout tidak memberikan pengaruh yang signifikan terhadap peningkatan kapasitas sambungan tubular (tubular joint). Sedangkan tebal chord dalam dan luar keduanya memberikan pengaruh yang signifikan terhadap peningkatan kapasitas sambungan tubular. Dari perbandingan diperoleh hasil-hasil analisis metode elemen hingga cukup mendekati hasil-hasil berdasarkan peraturan API RP 2A WSD dan hasil persamaan API RP 2A WSD umumnya ada pada sisi konservatif kecuali pada kasus beban momen keluar bidang.

Author Biographies

Made Suarjana, Civil and Environmental Engineering Faculty, Institut Teknologi Bandung, Lebak Siliwangi, Coblong, Bandung City, West Java, 40132,

Lektor Kepala

Teknik Sipil

Bayu Purnama A. Malida, PT. Waskita Karya

Engineer

References

ABAQUS (2011), "ABAQUS/CAE 6.11 User's Manual" . Online Documentation Help: Dassault Systmes.

API RP 2A-WSD (2007), API Recommended Practice for Planning, Designing, and Construction Fixed Offshore Platform Working Stress Design, American Petroleum Institute (API), USA.

Gomes, N. V., L.R.O. de Limaa, P.C.G. da S. Vellascoa, A.T. da Silvaa, M.C. Rodriguesa, L.F. Costa-Nevesc, (2019), "Experimental and numerical investigation of SHS truss T-joints reinforced with sidewall plates" , J. of Thin-Walled Structures, 145: 106404

Melek, P. G., Hussein, M. and Gaawan, S. (2017), "Confining T-joints by adding two outer hollow ring flanges welded to additional hollow circular pipe" , Canadian Journal of Civil Engineering, 44(10): 783-801

Norsok Standard N-004 (Rev. October 2004) : Design of steel structures, Standard Norway.

Pecknold, D. A, Park, J.B., and Koppenhoefer, K.C., (2001), "Ultimate Strength of Gap K Tubular Joint with Chord Preloads" , in Proceedings os OMAE'01 20th International Conference on Offshore Mechanics and Arctic Engineering, Rio de Jeneiro, Brazil.

Shen, W. and Choo, Y. S. (2012), "Stress Factor for a Tubular T-joint with Grouted Chord" , J. Engineering Structure, 35:37-47

Shengzhi, S., Yongbo, S., (2011), "Static Strength of Tubular T-joint with Reinforced Chord Under In-plane Bending Load" , The Open Ocean Engineering Journal, 4: 65-70

Shubin, H.E., Yongbo, S., and Hongyan, Z., (2013), "Static Strength of Circular Tubular T-joints with Inner Doubler Plate Reinforcement Subjected to Axial Compression" , The Open Ocean Engineering Journal. 6: 1-7

Suarjana, M., Kurnia, M.,(2013), "Pengujian Perumusan Code API (American Petroleum Institute) untuk Joint Baja Tubular tidak Digrout dan Digrout dengan Metoda Elemen Hingga" , Jurnal Teknik Sipil, Institut Teknlogi Bandung, 20(3): 195-206

Swensson, K. D., Yura J. A., (1987), Ultimate Strength of Double-Tee Tubular Joint: Interaction Effects, PMFSEL Report No. 87-9, The University of Texas, Austin, USA.

Thorenfeldt, E. Tomaszewicz, A. dan Jensen J. J., (1987), "Mechanical properties of high-strength concrete and application in design," Proceedings of Symposium on Utilization of High-Strength Concrete, Tapir, Trondheim, Norway.

Van der Vegte, G.J., Makino, Y., and Wardeiner, J., (2002), "The Effect of Chord Pre-load on The Static Strength of Uniplanar Tubular K-Joints" , Proceedings of The Twelfth Offshore and Polar Engineering Conference. Kitakyushu, Jepang.

Wei, S. (2011), Behaviour of Grout Infilled Steel Tubular Members And Joints, Ph. D. Thesis, National University of Singapore, Singapore.

Yura, J. A., Zettlemoyer, N. A., and Edwards, I. F. (1980). "Ultimate Capacity Equations for Tubular Joints" . Offshore Technology Conference. Houston, Texas, USA.