Analisis Perancangan Dinding Penahan Tanah Untuk Seawater Intake Pembangkit Listrik Tenaga Uap

Authors

  • Ibadurrahman Adz Dzikro Program Studi Magister Teknik Sipil - Fakultas Teknik Sipil dan Lingkungan, Institut Teknologi Bandung
  • Sarah Via Mades Aweka Program Studi Magister Teknik Sipil - Fakultas Teknik Sipil dan Lingkungan, Institut Teknologi Bandung
  • Azka Syarifa Amani Program Studi Magister Teknik Sipil - Fakultas Teknik Sipil dan Lingkungan, Institut Teknologi Bandung
  • Harum Kurnia Jayanti Program Studi Magister Teknik Sipil - Fakultas Teknik Sipil dan Lingkungan, Institut Teknologi Bandung
  • Andika Sahadewa Lecturer - Geotechnical Engineering Research Group, Faculty of Civil and Environmental Engineering

DOI:

https://doi.org/10.5614/jts.2024.31.2.9

Keywords:

retaining walls, sea water intake, MIDAS GTS NX, secant pile, mohr-coulumb, ground anchor

Abstract

Abstract

The handling of retaining walls in the PLTU seawater intake project is a crucial part in maintaining the stability of buildings below ground level. The retaining wall construction is selected based on the depth of excavation, soil type, the height of the Groundwater Table (GWT), and the load being retained. The lateral force calculation method uses Rankine and Coulomb theories with specified soil parameters. The case study was conducted at the seawater intake area of Java 9 & 10 Suralaya PLTU in Suralaya, Cilegon, Banten. The design process involved soil data interpretation, site class determination, and stability analysis using MIDAS GTS NX software. The retaining wall design is divided into two parts, using diaphragm walls and secant piles. The use of lateral reinforcement in the form of soil anchors is adjusted to the provisions of SNI 8460-2017. The design results show that the wall and anchor configurations meet the design criteria, with appropriate values of safety numbers and lateral deflections. However, the selection of Mohr-Coulomb soil model and pseudostatic earthquake analysis produced more conservative results. In conclusion, the retaining wall design proved to be effective in handling the lateral soil loads and pressures in the seawater intake PLTU project.

References

Ameratunga, J., 2021, Correlations of Soil and Rock Properties in Geotechnical Engineering, Springer.

Bowles, J. E., 1997, Foundation Analysis and Design (8th ed.), Cengage Learning, Stamford.

Conte, E., & Troncone, A., 2018, Simplified Analysis of Cantilever Diaphragm Walls in Cohesive Soils, Soils and Foundations, 58(6), 1446?1457. https://doi.org/10.1016/j.sandf.2018.08.012

Das, B. M., 2014, Principles of Foundation Engineering (8th ed.), Cengage Learning, Stamford.

European Committee for Standardization, 1997, Geotechnical Design: Eurocode EC7, CEN, Brussels, Belgium.

Evangelista, A., di Santolo, A. S., & Simonelli, A. L., 2010, Evaluation of Pseudostatic Active Earth Pressure Coefficient of Cantilever Retaining Walls, Soil Dynamics and Earthquake Engineering, 30, 1119?1128. https://doi.org/10.1016/j.soildyn.2010.04.001

MIDAS, 2019, GTS NX User Manual, MIDAS, Providence.

Nasional, B. S., 2017, SNI 8460-2017: Persyaratan Perancangan Geoteknik, Badan Standarisasi Nasional, Jakarta.

Nasional, B. S., 2019, SNI 1726-2019: Tata Cara Perancangan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Nongedung, Badan Standarisasi Nasional, Jakarta.

Osman, A. S., & Bolton, M. D., 2004, A New Design Method for Retaining Walls in Clay, Canadian Geotechnical Journal, 41(3), 451?466. https://doi.org/10.1139/t04-003

Osman, A. S., & Bolton, M. D., 2006, Ground Movement Predictions for Braced Excavations in Undrained Clay, Journal of Geotechnical and Geoenvironmental Engineering, 132(4), 465?477. https://doi.org/10.1061/(ASCE)1090-0241(2006)132:4(465)

Padfield, C. J., & Mair, R. J., 1984, Design of Retaining Walls Embedded in Stiff Clays, Report 104, Construction Industry Research and Information Association, London.

Prakash, S., & Sharma, H. D., 1990, Pile Foundations in Engineering Practice, John Wiley & Sons, Toronto.

Sabatini, P. J., et al., 1999, Geotechnical Engineering Circular No. 4: Ground Anchors and Anchored Systems, U.S. Department of Transportation Federal Highway Administration.

Seed, H. B., & Whitman, R. V., 1970, Design of Earth Retaining Structures for Dynamic Loads, ASCE Specialty Conference, Lateral Stresses in the Ground and Design of Earth Retaining Structures, Cornell University, Ithaca, New York, 103?147.

Swami Saran, 1990, Displacement Dependent Earth Pressure in Retaining Walls, Indian Geotechnical Journal, 20, July 1990.

Published

2024-08-22

How to Cite