Design and Development of a Low-Cost IoT-Based Portable Pulse Oximeter
Keywords:
BPM, SPO2, Pulse Oximeter, max30100 sensorAbstract
Real-time monitoring of heart rate and oxygen saturation is commonly performed using conventional medical devices that are impractical for daily use. This study aims to design a low-cost, Internet of Things (IoT)-based portable pulse oximeter prototype for real-time health monitoring. The system employs a MAX30100 sensor to measure BPM and SpO₂, an ESP32 microcontroller for data processing, and an OLED to display the results. The measured data are also transmitted to the Blynk application for remote smartphone monitoring. Performance was evaluated on 20 participants consisting of 10 men and 10 women, by comparing the measurement results with those of the commercial Serenity OX-48 pulse oximeter. System performance was assessed using accuracy, Mean Absolute Error (MAE), standard deviation, and Pearson correlation. The male group achieved an average accuracy of 98.71% for BPM (MAE = 1.09 BPM; r = 0.99) and 99.16% for SpO₂ (MAE = 0.80%; r = 0.92). Meanwhile, the female group achieved an average accuracy of 98.88% for BPM (MAE = 1.01 BPM; r = 0.99) and 99.17% for SpO₂ (MAE = 0.80%). These results indicate that the system delivers accurate, stable, and reliable measurements and is suitable for real-time IoT-based physiological monitoring.
References
B. Furst and J. González-Alonso, “The heart, a secondary organ in the control of blood circulation,” Exp. Physiol., vol. 110, no. 5, pp. 649–665, 2025. https://doi.org/10.1113/EP091387
M. S. Amran, N. B. Bahar, and S. Akash, “Perspective chapter: physiology and pathology of the cardiovascular system,” Nov. Pathog. Treat. Cardiovasc. Dis., Aug. 23, 2023. https://doi.org/10.5772/intechopen.108355
P. A. Heidenreich et al., "2022 AHA/ACC/HFSA guideline for the management of heart failure: A report of the American College of Cardiology/American Heart Association Joint Committee on clinical practice guidelines," Circulation, vol. 145, no. 18. 2022. https://doi.org/10.1161/CIR.0000000000001063
S. M. Perman et al., “2023 American Heart Association. Focused update on adult advanced cardiovascular life support : An update to the American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care,” Circulation, vol. 149, no. 5, pp. E254–E273, 2024. https://doi.org /10.1161/CIR.0000000000001194
A. S. Sholikhah, C. Susilo, and M. A. Hamid, “Pengaruh pendidikan kesehatan resusitasi jantung paru terhadap kemampuan penangan pre hospital korban henti jantung pada karang taruna di kecamatan Balung,” ASSYIFA: J. Ilmu Keshnt., vol. 2, no. 2, pp. 250–255, 2024. https://doi.org/10.62085 /ajk.v2i2.69
R. B. Brown, “Phosphate toxicity and SERCA2a dysfunction in sudden cardiac arrest,” FASEB J., vol. 37, no. 7, pp. 1–8, 2023. https://doi.org/10.1096/fj.202300414r
A. Haedar, A. Y. Nagara, B. Soenarto, H. Tanjoyo, A. Josafat, and J. Johannes, “EMS system performance for sudden cardiac arrest in Malang - Indonesia,” Malaysian Journal of Medicine and Health Sciences, no.21 (4), pp. 144 - 151, July 2025. https://doi.org/10.47836/mjmhs.21.4.19
K. D. Ana and A. Kusyani, “Pengetahuan bantuan hidup dasar dengan tingkat kecemasan keluarga pada pasien henti jantung,” J. Educ. Res., vol. 4, no. 1, pp. 100–106, 2023. https://doi.org/10.37985/jer.v4i1.131
L. W. Andersen, W. Y. Kim, M. Chase, K. M. Berg, S. J. Mortensen, A. Moskowitz, V. Novack, M. N. Cocchi, and M. W. Donnino, "The prevalence and significance of abnormal vital signs prior to in-hospital cardiac arrest," Resuscitation, vol. 98, pp. 112-117, 2016.
https://doi.org/10.1016 /j.resuscitation.2015.08.016
C. H. Lin, S. L. Cheng, C. Z. Chen, C. H. Chen, S. H. Lin, and H. C. Wang, “Current progress of COPD early detection: key points and novel strategies,” Int. J. COPD, vol. 18, no. July, pp. 1511–1524, 2023. https://doi.org/10.2147/copd.s413969
D. Park, K. So, S. K. Prabhakar, C. Kim, J. J. Lee, J.-H. Sohn, J.-H. Kim, S.-H. Lee, and D.-O. Won, “Early warning score and feasible complementary approach using artificial intelligence-based bio-signal monitoring system: A review,” Biomedical Engineering Letters, vol. 15, pp. 717–734, 2025. https://doi.org/10.1007/s13534-025-00486-4
L. P. Serrano et al., “Benefits and Challenges of remote patient monitoring as perceived by health care practitioners: systematic review,” Perm. J., vol. 27, no. 4, 2023. https://doi.org/10.7812/TPP/23.022
D. S. Silver et al., “Association between timing of operative interventions and mortality in emergency general surgery,” Trauma Surg. Acute Care Open, vol. 9, no. 1, pp. 1–9, 2024. https://doi.org/10.1136/tsaco-2024-001479
K. Zhang et al., “National Early Warning score does not accurately predict mortality for patients with infection outside the intensive care unit: A systematic review and meta-Analysis,” Front. Med., vol. 8, no. July, pp. 1–10, 2021. https://doi.org/10.3389/fmed.2021.704358
S. Dewi, F. A. Zahroh, and F. Firdaus, “Sistem monitoring of heart rate and blood oxygen automatic oximeter+ berbasis Internet of Things (IOT),” Kappa J., vol. 7, no. 2, pp. 294–299, 2023. https://doi.org/10.29408/kpj.v7i2.20318
K. A. Mayuga et al., “Sinus Tachycardia: A multidisciplinary expert focused review,” Circulation: Arrhythmia and Electrophysiology, vol. 15, no. 9, 2023. https://doi.org/10.1161/CIRCEP.121.007960
F. Michard and B. Saugel, “New sensors for the early detection of clinical deterioration on general wards and beyond - a clinician’s perspective,” J. Clin. Monit. Comput., vol. 39, no. 2, pp. 435–442, 2025. https://doi.org/10.1007/s10877-024-01235-1
B. Yulianti and I. Prakoso, “Rancang bangun pulse oximeter menggunakan aplikasi Blynk,” J. Teknol. Ind., vol. 12, no. 1, pp. 14–20, 2023. https://doi.org/10.35968/jti.v12i1.1043
R. S. Septiar, A. Situmeang, and V. E. Kristianti, “Prototype pengukur detak jantung, saturasi oksigen, dan suhu tubuh manusia secara portable,” J. Tek. dan Sci., vol. 3, no. 2, pp. 84–93, 2024. https://doi.org/10.56127/jts.v3i2.1535
M. Z. H. Kolk, S. Ruipérez-Campillo, A. A. M. Wilde, R. E. Knops, S. M. Narayan, and F. V. Y. Tjong, “Prediction of sudden cardiac death using artificial intelligence: Current status and future directions,” Hear. Rhythm, vol. 22, no. 3, pp. 756–766, 2025. https://doi.org/10.1016/j.hrthm.2024.09.003
Published
How to Cite
Issue
Section
Copyright (c) 2026 Indri Desriani, Mona Berlian Sari

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
An author who publishes in the Jurnal Otomasi Kontrol dan Instrumentasi agrees to the following terms:
- The author retains the copyright and grants the journal the right of first publication of the work simultaneously licensed under the Creative Commons Attribution-ShareAlike 4.0 License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal
- Author can enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book) with the acknowledgement of its initial publication in this journal.